PRCD-K protective extension or distributor IP 44 according to DGUV-I 203-032 for operation on power generators :
DGUV Information 203-032 requires appropriate protective measures when connecting two or more electrical devices to a power generator. PRCD-K meets these requirements and serves to increase the protection level. When used with submersible pumps, PRCD-K prevents the accidental triggering of the protective device and thus the shutdown of the submersible pump due to potential equalization currents.
- Fault currents caused by defective consumers are detected in fractions of a second and the power supply is interrupted
If you use a mobile power generator or a high-woltage battery like Instagrid on the set, a PRCD-K is strongly recommended
If you operate electrical devices, such as tools, via a power generator, make sure that each device is connected via a PRCD-K.
- Input rubber plug with 1.5 m cable
- Output rubber coupling with 1.5m cable
- PRCD-K 230V/50Hz, 16A, 0.03A
- Rated residual current: 30 mA
- Trigger time less than 30 ms
- max. 3,600 W
- Plastic housing with function display and test circuit
- special design for rough use on construction sites
- large, easy-to-use ON and OFF buttons
- optical switch position indicator
- Protection class of the PRCD-K IP55 the connectors have a separate protection class
Schuko Personal Protection - PRCD-K
PRCD-K protective extension or distributor IP 44 according to DGUV-I 203-032 for operation on power generators :
DGUV Information 203-032 requires appropriate protective measures when connecting two or more electrical devices to a power generator. PRCD-K meets these requirements and serves to increase the protection level. When used with submersible pumps, PRCD-K prevents the accidental triggering of the protective device and thus the shutdown of the submersible pump due to potential equalization currents.
- Fault currents caused by defective consumers are detected in fractions of a second and the power supply is interrupted
If you use a mobile power generator or a high-woltage battery like Instagrid on the set, a PRCD-K is strongly recommended
If you operate electrical devices, such as tools, via a power generator, make sure that each device is connected via a PRCD-K.
- Input rubber plug with 1.5 m cable
- Output rubber coupling with 1.5m cable
- PRCD-K 230V/50Hz, 16A, 0.03A
- Rated residual current: 30 mA
- Trigger time less than 30 ms
- max. 3,600 W
- Plastic housing with function display and test circuit
- special design for rough use on construction sites
- large, easy-to-use ON and OFF buttons
- optical switch position indicator
- Protection class of the PRCD-K IP55 the connectors have a separate protection class